OWNER’S MANUALHow to install, operate and maintain yourEcoWater SystemsAir Aspirated Iron FilterModels ETF AIV-10ETF AIV-127336313 (Rev. A 12/10/12)E
10ECOWATERS Y S T E M SProgramming the Electronic ControllerFIG. 12UP buttonDOWNbuttonDisplayRECHARGE buttonSELECT buttonCONTROLLER SETTINGS REQUIREDu
11ECOWATERS Y S T E M SProgramming (continued) & Controller Features / OptionsC. SET RECHARGE START TIME1. If you completed the previous step, the
12ECOWATERS Y S T E M SController Features / Options (continued)RECHARGE CYCLE TIME ADJUSTMENTSThe default setting for backwash and aspirate timesof t
13ECOWATERS Y S T E M SFeatures / Options (continued) & Routine MaintenanceFIG. 23FIG. 244. CHEMICAL FEEDER TRIP VOLUME: If you haveset the auxili
14MANUALLY INITIATED ELECTRONICDIAGNOSTICSUse the following procedures to advance the filterthrough the recharge cycles to check operation.Remove the
15ECOWATERS Y S T E M STroubleshooting (continued)RESETTING TO FACTORY DEFAULTSTo reset the electronic controller to its factory defaultfor all settin
16ECOWATERS Y S T E M STroubleshooting Guide & Wiring SchematicFIG. 33NO24VDCValvemotorPositionswitchNCTransformerBack of ElectronicController (PW
17ECOWATERS Y S T E M SRepair PartsKeyNo.Part No. Description1 7210478 Top Cover2 7275907 Transformer, 120 V to 24 V, 10 VA3 7259927 Wire Harness4 733
18ECOWATERS Y S T E M SRepair Parts5093929190897879777576Wear StripSealCross-sectionView6366676261605958575655547073727374945152536468696582AssembledV
19ECOWATERS Y S T E M SRepair PartsKeyNo.Part No. Description50 7224087 Screw, #8-32 x 1” (2 req.)51 7286039 Motor (incl. 2 ea. of Key No. 50)52 72313
2ECOWATERS Y S T E M STable of ContentsTABLE OF CONTENTSPageSpecifications & Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20ECOWATERS Y S T E M SWarrantyLIMITED WARRANTYEcoWater Systems LLC Advantage WarrantySeries ETF AIV Water SystemCongratulations! You have just purch
3ECOWATERS Y S T E M SSpecifications & DimensionsSIDE VIEW FRONT VIEWTOP VIEW14"14"INOUT3-3/4"IN - OUT39-1/4"44-3/4"ETF A
Recommended maximum allowable inlet waterpressure is 80 psi. Use a pressure reducing valve ifnecessary. Be sure the addition of a pressure reduc-ing
5ECOWATERS Y S T E M SBefore Starting InstallationWHERE TO INSTALL THE FILTER=Place the filter as close as possible to the pressuretank (well system)
ECOWATERS Y S T E M STypical Installation Illustrations6FIG. 4DrainFittingValveDrainHoseValveDrainHose1-1/2”Air Gap1-1/2”Air Gap1-1/2””Air Gap1-1/2” A
71. TURN OFF WATER SUPPLYa. Close the main water supply valve near the wellpump or water meter.b. Shut off the electric or fuel supply to the waterhea
8ECOWATERS Y S T E M SInstallationb. Place bypass valve(s) into “bypass” position. On asingle valve, slide the stem inward to BYPASS(See Fig. 4 on pa
9ECOWATERS Y S T E M SDescription of Operation & SanitizingService water enters the filter and passes through aircaptured at the top of the minera