Part No. 7291393 (Rev. H 6/24/08)
How to operate your
EcoWater Systems Water
Conditioner/Refiner
EcoWater Systems Conditioner
with Remote (ECR)
EcoWater Systems Refiner
with Remote (ERR)
SERIES
3500 & 3502
EcoWater Systems LLC
P.O. Box 64420, St. Paul MN 55164-0420
OWNER’S MANUAL
PRINTED IN U.S.A.
ERR 3500R20 & ERR 3502R30 are Tested
and Certified by WQA against NSF/ANSI
Standard 42 for chlorine taste and odor.
Systems Tested and Certified by NSF Interna-
tional and WQA against NSF/ANSI Standard
44 for water softening performance and the
reduction of barium and radium 226/228.
Zobrazit stránku 0
1 2 3 4 5 6 ... 43 44

Shrnutí obsahu

Strany 1 - OWNER’S MANUAL

Part No. 7291393 (Rev. H 6/24/08)How to operate yourEcoWater Systems WaterConditioner/RefinerEcoWater Systems Conditionerwith Remote (ECR)EcoWater Sy

Strany 2 - ECOWATER

10CONNECTING TO REMOTEWhen the conditioner/refiner’s electronic control is firstpowered up, it is not yet in communication with theremote. Do the fol

Strany 3 - GUARANTEE

LOW SALT ALARMUse this feature to program when the electronic controlwill display a low salt alarm. The number of days canbe customized, or the featu

Strany 4 - Planning Installation

12FIG. 292. Make sure Recharge is highlighted (See Figure 28).3. Press the SELECT () button to display theRecharge menu (See Figure 29).FIG. 284. If

Strany 5 - Unpacking & Installation

SETTING RECHARGE TIMEWhen the conditioner/refiner’s electronic control is firstpowered up, the default time for starting an automaticrecharge is 2:00

Strany 6 - Installation

14MODIFYING ROLLING SCREENSDuring normal conditioner/refiner operation, four statusscreens are shown in sequence (See “Conditioner/Refiner Status Scre

Strany 7

SETTING TIME FORMATUse this feature to select a 12-hour (AM/PM) or 24-hourclock.1. From any of the rolling status screens, press theSELECT () button

Strany 8

16SYSTEM INFORMATIONUse these features to look up the following informationabout the conditioner/refiner and its operations:Model information (model

Strany 9

CYCLE TIMESUse these features to change the following conditioner/refiner operations:Backwash timeSecond backwash (On/Off)Second backwash timeFast

Strany 10 - Conditioner/Refiner Operation

18SPECIAL FEATURESUse these features to change the following operations:Efficiency modeMaximum days between rechargesAuxiliary control (described o

Strany 11

19FIG. 75FIG. 76FIG. 73AUXILIARY CONTROLThe electronic control has an auxiliary output which cancontrol external devices in a water treatment system.T

Strany 12

2SAFETY GUIDESFollow the installation instructions carefully. Failure toinstall the EcoWater Systems conditioner/refiner proper-ly voids the warranty

Strany 13

20FIG. 78FIG. 79SERVICE REMINDER (set / reset)Use this feature to program the number of months (upto 24) before a “Service overdue” message will appea

Strany 14

21DIAGNOSTICSThis feature allows a service technician to check theoperating state of individual components in the condi-tioner/refiner (e.g. valve pos

Strany 15

22UNPACKINGThe EcoWater Systems HydroLink™ remote is shippedfrom the factory in one carton. Thoroughly check forpossible shipping damage and parts lo

Strany 16

23HYDROLINK™ REMOTEThe EcoWater Systems HydroLink™ remote is part of awireless system which monitors multiple water treat-ment devices in a home. The

Strany 17

24AlertTMFIG. 94DisplayLEFTButtonRIGHTButtonUPButtonDOWNButtonAlertLEDSELECTButtonADDING A DEVICETo initiate communication between the remote and adev

Strany 18

FIG. 99FIG. 100FIG. 1012. Press the remote’s SELECT () button to display thedevice menu.3. Press the DOWN () button to scroll through themenu option

Strany 19

26SETTING THE LANGUAGELanguage is set independently on the remote and con-ditioner/refiner (See Page 14 to set the conditioner/refiner’s language). F

Strany 20

27This feature may be used to assure an adequate supplyof conditioned water at times of unusually high wateruse. For example, if you have guests and

Strany 21

28CHANGING WHICH DATA ITEMS ARE DIS-PLAYED IN THE STATUS SCREENSEach device added to the remote (conditioner/refiner,drinking water system, etc.) has

Strany 22 - (156 mm)

29CHANGING WHICH DATA ITEMS MAY BEREMOTELY CONTROLLEDSome devices (conditioner/refiners, for example) have alist of data items which may be controlled

Strany 23 - Remote Introduction

3LIMITED WARRANTYEcoWater Systems LLCAdvantage WarrantySeries ECR & ERR 3500 Water SystemCongratulations! You have just purchased the highest qua

Strany 24 - Remote Operation

30ECOWATERSYSTEMSRemote OperationFIG. 123FIG. 125FIG. 127FIG. 124FIG. 1262. Press the remote’s SELECT () button to display thedevice menu (See Figure

Strany 25

REFILLING WITH SALTIf the conditioner/refiner uses all the salt before more isadded, hard water will result. Lift the brine tank lid andcheck the sal

Strany 26

32CLEANING THE NOZZLE & VENTURIA clean nozzle & venturi (See Figure 129) is necessaryfor the EcoWater Systems conditioner/refiner to workprope

Strany 27

33ECOWATERSYSTEMSService InformationRELIEVING WATER PRESSURE WITH THEBYPASS VALVE(S)CAUTION: Always relieve water pressure in theEcoWater Systems cond

Strany 28

34PROBLEM CAUSE CORRECTIONRemote display showsquestion marks (?)instead of numbersLoss of signal between conditioner/refiner and remote.Make sure cond

Strany 29

35AUTOMATIC ELECTRONIC DIAGNOSTICSThis conditioner/refiner has a self-diagnostic function forthe electrical system (except for input power and/orwater

Strany 30

36TROUBLESHOOTING -MANUAL ADVANCE RECHARGE CHECKThis check verifies proper operation of the positionswitch, gear motor, brine tank fill, brine draw, r

Strany 31 - Service Information

37WIRING SCHEMATIC124VDC MOTORTRANSFORMER24VAC120V60 HzBACK OF FACEPLATECONTROL BOARD ONSWITCHPOSITIONNO+5GNDOUTTURBINESENSORRedBlackRedBlackWhiteBrow

Strany 32

38ECOWATERSYSTEMSDimensionsINOUT3--13/16”32--1/2”45--1/8”AIN -- OUTIN -- OUT14”20”14”14”CB16”16”36--9/16”32”FIG. 138ModelNominal ResinTank SizeDimensi

Strany 33 - Water Flow

39ECOWATERSYSTEMSSpecifications Efficiency ratings are only valid at the lowest salt dosage and service flow rate. These units were efficiency rated

Strany 34 - TROUBLESHOOTING GUIDE

4INLET / OUTLET PLUMBING OPTIONS ALWAYS INSTALL either an EcoWater Systems bypassvalve #7214383, or a 3-valve bypass system. Bypassvalves allow you

Strany 35

40ECOWATER SYSTEMS CONDITIONER/REFINER ASSEMBLY12Valve AssemblySee Pages 42 & 43for parts346736591011812293938404142431335343332303126271720211816

Strany 36

41ECOWATER SYSTEMS CONDITIONER/REFINER ASSEMBLYKeyNo.Part No. Description1 7275907 Transformer, 24V, 10VA2 7292967 Repl. Remote (incl. batteries)3 721

Strany 37

42VALVE ASSEMBLY70655965636268696460616770665758565554535251508471727374757677808182787989836263618887868590919897969992939495ECOWATERSYSTEMSRepair Pa

Strany 38 - Dimensions

43VALVE ASSEMBLYKeyNo.Part No. Description507101548Turbine Assembly(ECR 3500R20, ERR 3500R20,ECR 3500R30, ECR 3502R30)7123061Turbine Assembly(ERR 3502

Strany 39 - Specifications

EcoWater Systems LLCP.O. Box 64420, St. Paul, MN 55164-04201-800-86WATERECOWATERSYSTEMS

Strany 40 - Repair Parts

5e. Make sure the brine tank cover is properly positioned onthe tank.3. INSTALL BYPASS VALVE and/or COPPERTUBESa. If installing an EcoWater Systems By

Strany 41

67. CONNECT INLET & OUTLET PLUMBINGa. SOLDERED COPPER(1) Thoroughly clean and flux all joints.(2) Pull the plastic “C'' clips and remove

Strany 42 - VALVE ASSEMBLY

712. PRESSURE TESTING FOR LEAKSTo prevent excessive air pressure in the EcoWaterSystems conditioner/refiner and plumbing system, dothe following steps

Strany 43

8SETUP PROCEDUREWhen the EcoWater Systems conditioner/refiner isplugged in for the first time, a beep sounds and the dis-play briefly shows a logo, fo

Strany 44

9During normal operation (status screens rolling), pressthe conditioner/refiner’s SELECT () button to displaythe Main menu (See Figure 16). This men